Some manufacturers have used tensile shear overlap specimens and defined the fixture time as the time required to develop a certain amount of psi of bond strength, often measured by the assembled bond being able to lift a specified weight. However, different manufacturers use different weights and times. You will have to choose your adhesive and then actually determine the shortest time to actually handle your parts.